Quantcast
Channel: Ivanti User Community : All Content - Patch Manager
Viewing all articles
Browse latest Browse all 1121

Error: "Failed to apply compliance settings" during vulnerability scan return code 451

$
0
0

Issue

"Failed to apply compliance settings" during vulnerability scan.

 

Steps to reproduce issue

 

  1. Right click on the device to run compliance scan, it gives error "unable to get compliance settings from core"
  2. Error in vulscan log:

Loaded 0 custom variables from C:\ProgramData\vulScan\CustomVariables.CoreServerHostName.ini

Last status: Could not find compliance settings

Error: No compliance behavior specified, unable to perform compliance scan

Failed to apply compliance settings

Last status: Failed

 

 

Resolution

In agent settings, create a new compliance setting, and then run a change settings task to deploy the settings to client machine.